Safety ribbon switches (conforming to EN1760/2)
Are made of a special PVC sheath within which is housed the sensor element which provides an electrical signal when any external crushing action is exerted on the board. A profile of aluminum plate complete the device for its attachment to the machine.
These devices are designed to prevent injury to personnel against crushing by moving parts as sliding doors, gates, elevators plans etc. detecting an electrical contact via a control circuit.
The system is guaranteed for a security level 1 or 3 "FAIL SAFE" in accordance with the use of control units and the number of conductors connected to the ribbon switches.
See accessories on catalog 2009 at p. 34-35
- Applications
- Aluminum guide
- Ribbon switches standard
For industrial use:
- emergency switches on each type of machine
- commands along the conveyor belts
- sliding door protections, etc..
For civil use:
- segnalazioni di ingressi per apertura porte
- comandi per disabili
- allarmi per banche
- azionamento cronometri sportivi per piscine
Chemical features:
-
Excellent resistance to:
- kerosene-oil-petrol
- acids and alkali
- alcohol and normal detergents
- tetracloride
Low resistance to:
- acetone-petrol
- ketone clorid-metilene
Electrical characteristics:
-
Voltage 32 V DC / AC
-
Current 1 A max.
-
Dielectric strength 1000 V / DC
-
Electrical resistance 0.3 ohm / Mt
-
Temperature -15 +60 ° C
-
Degree of protection IP 67
-
Duration of operation 3 million operations
-
PVC coating material
-
Typical Weight 80 gr. / Mt
Type 406 (for types 202-L) in plastic too
| Ribbon switches | 102-A | 102-F | 202-L |
|---|---|---|---|
| Profile | ![]() |
||
| Dimensions | 14 x 4 mm | 14 x 8,5 mm | 19 x 5 mm |
| Crushing strength | 0,2 Kg | 1,5 Kg | 0,5 Kg |
| Radius of curvature | 10 mm | 60 mm | 15 mm |
Type of terminals
| Terminals sealed welding for any sensor | type LD or D for models 102-A and 102-F with wire 500 mm |
![]() |
![]() |
| Terminals sealed with connectors | type C only for model 202-L with wire 500 mm |
![]() |
![]() |


Type 404 (for types 102-A and 102-F)